News · In-depth analysis

BESS and cybersecurity: protecting energy, data, and access

Enterprise-wide aggregation can include batteries, power conversion, local control, and remote services. Cybersecurity must be coordinated with electrical and operational security: knowing who is communicating with whom is part of the project, not a detail to be left to the first connection.

Published on April 20, 2026

Storage containers next to photovoltaic modules and a corporate building. Original uSolar logo at the bottom right.

Three points to keep in mind

01

Document the devices, flows, and authorized personnel.

02

Coordinates access and updates with the IT manager.

03

Check separately for Internet loss, failure, and blackout.

01 / In Depth

First draw the system map

The battery BMS controls module parameters and limits; the EMS coordinates energy strategies and exchanges with other devices. Gateways, inverters, meters, and cloud platforms can complete the architecture. Components and dependencies change between products: not all functions require the same connection.

A useful documentation lists the necessary devices, versions, interfaces, and flows. It must distinguish between those who can only read data and those who can modify power, schedules, or settings. The presence of a dashboard alone does not demonstrate the existence of full remote control, nor that every function remains available without an Internet connection.

02 / In Depth

Nominal access and defined responsibilities

The access rights of the owner, the maintainer, and the manufacturer’s support should have roles and privileges consistent with the activities. Shared credentials should be avoided, multi-factor authentication should be used where available, and access revocation should be provided when the person in charge changes.

For remote access to the system operating the plant, the IT manager and the suppliers must agree on the channel, permissions, and traceability. An always open connection is not an implicit requirement of the support: the methods are chosen based on the risk and the functions actually required.

The scheme

A chain of verifiable accountability

Organizational structure: each step has a contact person and a documented result.

01

Inventory and flows

02

Accesses and roles

03

Monitoring and updates

04

Response and restoration

Conceptual scheme, not an executive network architecture.

The BESS protections remain those provided by the project and by the manufacturer.

03 / In-depth analysis

Separating the networks without compromising their functionality

The energy management network should not be treated as a normal network for guests. Segmentation and communication rules help to limit connections to those that are necessary and to contain the spread of a problem.

These choices must, however, comply with manufacturer requirements, protections, and process continuity. Devices are not disconnected or firewalls are changed blindly: the flows are documented, the changes are agreed upon, and it is verified that measurements, alarms, and controls still function. The NIST guidelines for OT combine security, reliability, and constraints from the physical world.

04 / In Depth

Updates, logs, and configurations recoverable

A digital maintenance plan establishes who receives the manufacturer’s notifications, evaluates updates, and chooses a window compatible with the activity. Recovery procedures are supported, protected copies of configurations are available when required, and changes made are recorded.

Logs should be used to identify anomalies, not just to accumulate files. Unexpected access, configuration changes, and loss of communication require reporting criteria and responsible parties. Data storage and access should be proportionate to their content and the needs of the organization.

05 / In-depth

Absent internet and absent electricity network are two different scenarios

A connection failure can interrupt remote monitoring while some local functions continue: it depends on the architecture. A power outage, on the other hand, raises the issue of backup and island operation, which is only possible if the system is designed and configured to do so.

A concrete plan describes for each scenario available functions, safe behavior, people to contact, and conditions for resuming operations. The tests must be agreed upon with the technicians and with the production activity. Continuity cannot be inferred from the mere number of kWh installed or from the availability of an app.

06 / In Depth

What to ask before delivery

Alongside the electrical schematics, it is useful to receive the communication map, the list of roles, the assistance procedures, the responsibilities for updates, and the procedures for an anomaly. Digital verifications involve the company, IT managers, the designer, the installer, and the manufacturer, according to their respective competencies.

Cybersecurity does not replace electrical, thermal, and fire safety checks. Furthermore, purchasing a BESS does not automatically make every company subject to the same regulatory obligations: the sector, size, and role of the organization require a separate assessment.

The most frequently asked questions

No. Architecture, configuration, access management, and maintenance are important. Connection requires defined responsibilities.

It depends on the system. The local and cloud functions must be documented and verified with the manufacturer.

It is part of management. It also requires roles, controlled communications, updates, and a plan for response and recovery.

×