News · In-depth analysis

South-facing or east–west roof: which solar PV layout suits your building?

A roof that is not perfectly oriented to the south does not automatically preclude photovoltaic panels. Orientation, inclination, shade, and consumption must be considered together: the design must compare feasible configurations, not choose an ideal direction while ignoring the building.

Published on March 25, 2026

Tile roof with photovoltaic modules near trees. Original uSolar logo at bottom right.

Three points to keep in mind

01

Compare the production profile, in addition to the annual total.

02

Evaluate shadows and lighting throughout the year.

03

Do not attribute automatic advantages to an orientation.

01 / In Depth

The production has a form, in addition to a total

Orientation changes the way production is distributed during the day. An area exposed to the east and one to the west receive light at different times; a multi-slope configuration can therefore have a different profile from a single slope.

This does not mean that East-West always produces more or guarantees greater self-consumption. The result depends on the site, the layout, and the coincidence with the loads. The comparison must include both the overall energy and its temporal evolution.

02 / In Depth

The inclination must be considered together with the other constraints.

The slope affects the solar availability on the surfaces and interacts with the mounting. On flat roofs, the arrangement and distances between rows can change the usable surface area and mutual shading.

The configuration is not decided solely by a theoretically favorable angle. Structure, wind, access, maintenance, and details of the roofing are all part of the evaluation. An energetically interesting solution must remain feasible and consistent with the building.

The scheme

Comparing the slopes using the same criteria

Orientation and inclination are evaluated along with shadows, mounting, and consumption.

01

Available surfaces

02

Orientation and inclination

03

Shades in the seasons

04

Production and consumption

05

Motivated configuration

No universal percentage for the South/East/West.

03 / In-depth analysis

The shadows require analysis throughout the year

An obstacle can have a different impact depending on the season and time of year. Therefore, control should not be limited to photographing a roof in the middle of the day in summer. Vegetation, buildings, and technical installations must be considered in their relationship with the sun's path.

In some cases it is advisable to exclude an area, reposition the modules or review the electrical configuration. In others, the shadow can limit the interest of the surface. The choice must be based on the data, without promising that an electronic device will eliminate the lack of light.

04 / In Depth

An example without automatic percentages

Imagine a building with an east and west facade and consumption distributed between morning and afternoon. The comparison can assess the use of both facades compared to a more economical solution, observing production and consumption within the same timeframe.

This is a project scenario, not a yield forecast. To quantify the result, we need locations, inclinations, shadows, and configuration. A simulation with documented assumptions allows us to compare the alternatives without assigning the same advantage to every east-west roof.

05 / In-depth

How to read a credible proposal

Ask that the proposal distinguish between used surfaces, installed power, and estimated production. If two configurations are compared, the assumptions should be homogeneous and the differences explained: it is not enough to juxtapose two annual figures without describing the assembly process.

It is also useful to understand which checks remain open. The best project is not necessarily the one that takes up the most space, but the one that makes good use of the available surfaces and makes the relationship between the building, the energy produced, and the actual needs comprehensible.

For a roof with different slopes, ask for each orientation to remain identifiable in the comparison. A single total can hide differences that help organise loads and later interpret monitoring data, without treating a profile anticipated by the design as abnormal.

The most frequently asked questions

Not necessarily. Other guidelines can be evaluated using simulations and verifications related to the site.

No. The coincidence also depends on consumption and the actual configuration.

The effect of the shadow and the comparison with alternatives must be evaluated, without assuming the suitability or uselessness of the area.

×