News · In-depth analysis

New PV systems: self-consumption, Ritiro Dedicato and batteries

For a new installation in 2026, start by distinguishing the electricity used on site from the electricity exported to the grid. Italy’s Scambio sul Posto scheme is closed to new applications. That changes the financial assessment, but it does not make a battery compulsory.

Published on August 17, 2026

House with photovoltaic panels and equipment for energy management. Original uSolar logo at the bottom right.

Three points to keep in mind

01

Under Italy’s Ritiro Dedicato (RID) scheme, the producer is paid for electricity exported to the grid. Electricity bought from the grid is billed separately.

02

Annual production and annual demand do not demonstrate autonomy.

03

Battery is a choice to be simulated, not a general requirement.

01 / In Depth

Scambio sul Posto: closure to new applications and existing contracts

The ARERA regulations set May 29, 2025 as the entry into service deadline for the plants admitted to the latest new access points, and September 26, 2025 as the deadline for submitting applications. A new plant that enters into service in 2026 must therefore not be proposed with a new SSP agreement.

This does not mean that all previous contracts have ended on the same date. Those who already have a contract should check the duration, the communications from GSE and the applicable regime. In the past, the SSP was also a regulated economic compensation: the network did not physically store the kWh of the individual producer.

02 / In Depth

What does the Ritiro Dedicato scheme pay for?

The RID is a simplified method of marketing the energy supplied through a convention with the GSE. The fees follow the rules of the service and the applicable prices; any guaranteed minimum prices require the conditions of eligibility stipulated.

The revenue from the sale does not correspond to the total price of the bill. A kWh consumed by the customer avoids a charge and the components applicable to that purchase; a kWh supplied generates a separate revenue item. It is not correct to multiply all the production by the average cost of the bill to estimate the savings.

The scheme

Producing more than consumption does not mean being self-sufficient

Demonstration day without energy storage: 9 kWh are used while the photovoltaic system produces.

Direct use of photovoltaics

Input/output residual

Production: 20 kWh

Direct use of photovoltaics: 9 kWh · Residual input/output: 11 kWh

Required power: 18 kWh

Direct use of photovoltaics: 9 kWh · Residual input/output: 9 kWh

The second segment represents grid exports in the first bar and grid imports in the second.

The direct use is the same flow seen in the two balances: it cannot be added together.

03 / In-depth analysis

Reading the energy balance without counting twice

Let’s consider an illustrative day without batteries: 20 kWh of production, 18 kWh of consumption, and 9 kWh used directly while the sun is producing. The balance sheet is simple: 11 kWh are injected and 9 kWh are purchased from the grid.

Production therefore covers half of the demand on that day, not all of it, although the total produced exceeds the consumed amount. The figure of 9 kWh produced requires comparison of the times; it cannot be derived by subtracting the two totals alone. In an annual forecast, the analysis must be repeated for different seasons and days.

04 / In Depth

Before adding a battery, check which loads you can move to daylight hours

When it is compatible with the needs of the home or business, scheduling some loads during production hours can increase direct usage. Vehicle charging, hot water, or programmable activities should be evaluated in conjunction with comfort, safety, and work organization.

Not all consumption is portable. Therefore, load management must be practical: what appliances, what times, and what limits? A generic timer does not replace measuring the surplus or verifying the available power.

05 / In-depth

The added value of energy storage

The battery can transfer part of the excess to subsequent hours. In the economic comparison, the cost of storage, losses, intended use, and the revenue from the sale that is foregone by charging it must be included. Not all the incoming energy is available again when it is discharged.

Usable capacity and power must be consistent with the loads. If power is also required during a blackout, configuration, served lines, autonomy, and switching must be defined. The energy reserved for backup has a different utility from that used every day to reduce drawdowns.

06 / In Depth

The questions to ask in the quote

A clear proposal separates estimated generation, self-consumption, electricity exported to the grid and remaining grid imports. It must state the prices used, operating costs, any incentives and technical conditions still to be checked. It is also useful to compare a less favourable scenario, without assuming constant prices or consumption throughout the system’s life.

RID and widespread self-consumption configurations are not synonymous: they follow different rules and their possible combination must be verified. The project starts with the data of the customer and the connection, then identifies the applicable tools.

The most frequently asked questions

No. What matters are investment, production, direct use, and the valorization of surpluses. The result must be calculated based on the actual case.

It is necessary to verify one’s own agreement and the communications from GSE. The closure of the new accesses does not coincide with the termination of all contracts at once.

No. Purchase and transfer are separate transactions. The costs not related to the kWh withdrawn must be considered separately.

×